Abstract

Cortex XSOAR indicators have an active or expired status which can be set to expire after a specific period or never to expire. Set default expiration method.

Indicators can have the Expiration Status field set to Active or Expired, which is determined by the Expiration field. When indicators expire, they still exist in Cortex XSOAR, meaning they are still displayed and you can still search for them. A job that runs every hour checks for newly expired indicators and updates the Expiration Status field.

When indicators expire, the expiration status and expiration fields are updated. You can use it to take actions based on indicator expiration. For more information, see Indicator field trigger scripts.

You can set the default expiration method for indicators either to never expire or to expire after a specific period. The default expiration method is set by the indicator type. For more information see Indicator type profile.

The following table shows the hierarchy by which indicators are expired.

Method

Description

Manual

Manually expire the indicator either in the indicator layout or CLI. This method overrides all other methods.

Note

You need a TIM license to access the indicator layout.

Use the expireIndicators command to change the expiration status to Expired for one or more indicators. This command accepts a comma-separated list of indicator values and supports multiple indicator types. For example, you can set the expiration status for an IP address, domain, and file hash: !expireIndicators value=1.1.1.1,safeurl.com,45356A9DB614ED7161A3B9192E2F318D0AB5AD10

Use the !setIndicator or for multiple indicators use the !setIndicators command to reset the indicators' expiration value. The value can also be set to Never, so that the indicators never expire. For example, !setIndicators indicatorsValues=watson.com expiration=Never.

You can also use these commands in a script, but the user can override this if running a command in the CLI or the indicator layout.

Feed integration

Some integrations support setting the expiration method on an integration instance level, which overrides the method defined for the indicator type.

Indicator type

The expiration method (interval or never) is defined according to indicator type, which applies to all indicators of this type. This is the default expiration method for an indicator.